Digital dental imaging: linking imaging systems to patient records

Imaging software and a practice management system can be linked in three main ways. This guide compares them, sets out what to record for every exposure and lists questions for both suppliers.

Maxillo editorialPublished 8 min read

This guide is for practice owners, managers and clinicians whose radiographs are captured in one system while the patient record is kept in another. It sets out how the two can be linked, what to record for every exposure, and what to ask both suppliers.

In brief: A link opens the imaging software on the patient you have open, copies images onto the record, or stores them using the DICOM standard. Whichever you have, your practice still decides where the justification, clinical evaluation and quality rating are written, where the original lives and who backs it up. Test any link on your own equipment before you rely on it.

Imaging software runs your sensors, phosphor plate scanner, OPG or CBCT unit and stores the images. Practices know it by names such as Carestream, Sidexis, Romexis or EzDent-i. Links between it and your practice management system (PMS) usually follow one of three patterns.

LinkWhat happensGood forWhat to watch
Launch (bridge)A button on the record opens that patient in the imaging softwareViewing the original with the imaging software’s own toolsUsually needs the imaging software on each computer; both systems must agree who the patient is
Import or attachA copy is added to the record; the original usually stays in the imaging softwareSeeing the image on the record itselfTwo copies to back up, retain and delete; the copy may be lower quality
DICOM storageImages are saved as DICOM files or sent to a DICOM archiveMoving images between systems with the patient ID inside each file“DICOM compatible” can mean export only

DICOM is an international standard for medical images. As the DICOM standard’s key concepts (opens in a new tab) explain, a DICOM file contains the patient ID within the file, and a Store service sends images to an archive, called a PACS. That model comes from hospital radiology, so ask whether your equipment can do it.

You can use the first two together. Report from the original in the imaging software. Treat a copy on the record as a reference image unless the supplier confirms it is suitable to report from and you view it on a screen that passes your display checks. Expect a CBCT volume to stay in the imaging software or a dedicated archive: one exported slice on the record is not the scan.

What the record should show for every exposure

In England, the CQC’s Dental mythbuster 8 on dental care records (opens in a new tab) says that if dental X-rays are taken, the justification, the report and the QA score should be recorded. The UK-wide Guidance Notes for Dental Practitioners on the Safe Use of X-ray Equipment (opens in a new tab) (2020) explain each:

  • Justification. The IR(ME)R practitioner should make a written record of the justification decision, and the identity of whoever justifies and authorises the exposure must be recorded.
  • Clinical evaluation (the report). It must cover the whole image, and for your own patients a record should be made within the patient’s notes.
  • Quality rating (the QA score). A separate process: on the recommended two-point scale, each image is rated diagnostically acceptable (A) or not acceptable (N).

In Great Britain, regulation 12(9) of IR(ME)R 2017 (opens in a new tab) says the employer must take steps to ensure that a clinical evaluation of the outcome of each exposure is recorded, in accordance with the employer’s procedures. Northern Ireland’s 2018 regulations (opens in a new tab), shown on legislation.gov.uk as originally made, set the same duty. Neither regulation says which software holds that record. Decide where the evaluation, the justification and the quality rating are each recorded, write it into your procedures, and ask your medical physics expert if you are unsure.

The Guidance Notes say that if no clinical evaluation takes place, this indicates that the radiograph was not justified. With images in one system and notes in another, check that no image is left without a recorded evaluation. For the note as a whole, see the clinical notes completeness checklist.

Where the original lives and who backs it up

Write down which system holds the original of each image, and confirm who backs it up. The GDC’s Standards for the Dental Team (opens in a new tab), which apply to registrants across the UK, say that if clinical records are computerised, registrants should make back-up copies of clinical records, radiographs and other images. If your PMS is cloud-hosted and your images stay on a server in the practice, do not assume the PMS supplier’s back-up covers them.

The same standards say radiographs form part of patients’ records, and that registrants must follow appropriate national advice on retaining, storing and disposing of patient records. That advice differs between England, Wales, Scotland and Northern Ireland, so check your nation’s current records code and ask your indemnifier. When records are destroyed, make sure no copy is left in the other system.

“We link to your imaging software” can mean several things. Some links only open the imaging software on the right patient. Others also send a thumbnail or a full image back to the record. Many match the two records on the patient number alone. A link may cover one version of a product and not the next, need extra software on each computer, or carry its own licence fee. Put the same questions to both suppliers in writing.

Ask both suppliers

  • Which exact products and versions does the link cover today, as opposed to planned?
  • Does it only open the imaging software, or also bring images back to the record?
  • What identifies the patient in both systems?
  • What happens to a patient’s images when two records are merged or a surname changes?
  • What has to be installed on each surgery computer?
  • Which company fixes the link when an update to either system breaks it?

Ask the imaging supplier

  • Is an image sent to the record the original file or a compressed copy?
  • Do the acquisition date and measurement calibration survive export?
  • Does each clinician sign in to the imaging software as themselves?
  • Is there a log of who captured, moved or deleted each image?
  • How are viewing licences counted across surgeries and reception?
  • If the product is described as DICOM compatible, what does it send, receive and store?
  • May we see its DICOM Conformance Statement?

Ask the practice management supplier

  • Can the link create the patient in the imaging software, so nobody types patients in by hand?
  • Where in your system do we record the justification, clinical evaluation and quality rating for each exposure?
  • Can those quality ratings be counted for our image quality audit?
  • Are images copied onto the record included in your back-up?
  • If patient numbers change when we move to or from your system, how is the link to existing images kept?

What to test on your own equipment

Use a dummy patient and a test image that does not belong to a patient. Take no exposure for the test, and repeat it after any major update to either system.

  • Create a dummy patient and open the imaging software from its record on every surgery computer.
  • Open a second patient straight afterwards and check the imaging software has changed patient too.
  • Attach the test image and compare it with the original on the screen you report from.
  • Rename the dummy patient and check its images are still found.
  • Merge the dummy patient with a duplicate and check the images are still found.
  • Ask whoever maintains your imaging server to restore the back-up to a separate location, then open an image from the restored copy.

A common way for an image to be misfiled is an exposure captured into the previous patient’s still-open imaging window. It helps to open the imaging software from the patient’s record immediately before each exposure and close that patient afterwards. A link does not replace your procedure for identifying the patient before exposure. Agree in advance who may move a misfiled image and how the move is recorded.

How Maxillo approaches this

In Maxillo, radiographs and photographs can be uploaded to the patient record and viewed in the browser, with the original file kept unaltered. A bridge that opens imaging software from the patient record is in development and has not been verified with any vendor’s software, so no imaging product is listed as supported. The help centre article on images on the record sets out how uploading and viewing work today.

Sources and further reading

This guide is general information for UK dental teams. It is not legal, regulatory or clinical advice. Rules differ between the four nations and change over time, so check the sources above and take your own advice before you rely on it.